Home / Products / Pad-Mounted Transformer / Oil-immersed single- phase pedestal Pad Mounted transformer
Oil-immersed single- phase pedestal  Pad Mounted transformer

Oil-immersed single- phase pedestal Pad Mounted transformer

Product Overview

Single-phase pad-mounted transformers are commonly used in residential areas to supply power to homes and small commercial buildings. They are designed to step down medium voltage to low voltage (e.g., 12kV to 120/240V) and are installed in a pad-mounted configuration for direct user power supply. These units are typically mounted on concrete pads and enclosed in tamper-resistant steel housings, making them suitable for public spaces. Single-phase units are compact, cost-effective, and easy to install, making them particularly ideal for space-constrained locations. 

More details

Technical Specifications

Primary Voltage Rating

 2.4 kV to 34.5 kV

Secondary Voltage Rating

 120/240V, 208V/120V, 480V/277V

Capacity Range

 10 kVA to 167 kVA

Phases

 Single-phases (1ph)

Rated Frequency

 50Hz or 60Hz

Internal Components

  1. Core Tank Assembly
    • Core:Constructed from high-permeability, low-loss cold-rolled grain-oriented silicon steel laminations with a single-phase closed magnetic circuit structure, achieving extremely low no-load losses.
    • Windings:High-voltage copper wire/foil windings on the outer layer, low-voltage windings on the inner layer (with center tap), offering excellent insulation and heat dissipation performance.
    • Insulating Oil:Fully immersed design, serving as the dielectric medium for insulation, heat dissipation, and arc extinction.
  1. High-Voltage Side Components
  • Wiring & Operation:Equipped with HV bushing wells (2 for loop feed, 1 for radial feed) and a submersible load-break switch (operated via external handle).
  • Dual Protection:Adopts a "dual-fuse" protection scheme — externally replaceable Bay-O-Net fuses for overload/secondary short-circuit protection; internal ELSP current-limiting backup fuses to intercept severe short-circuit faults.
  • Voltage Regulation:Equipped with a no-load tap changer for manual adjustment of the turns ratio to adapt to grid voltage fluctuations.
  1. Low-Voltage Side Components
  • Output Terminals:Equipped with high-current bolt-type bushings (X1-X3 and neutral grounding terminal X0), with output voltage e.g. 120/240V.
  • Center Tap Grounding:The neutral wire is drawn out through the center tap of the low-voltage winding, simultaneously providing two voltage levels e.g. 120V (for household appliances) and 240V (for high-power equipment).
  1. Safety & Monitoring
  • Pressure Relief:Automatic PRV for pressure venting and explosion protection.
  • Status Monitoring:Integrated visual oil window + high-voltage dual-fuse oil temperature protection.
Product Specifications Details

Technical Specifications

Primary Voltage Rating

 2.4 kV to 34.5 kV

Secondary Voltage Rating

 120/240V, 208V/120V, 480V/277V

Capacity Range

 10 kVA to 167 kVA

Phases

 Single-phases (1ph)

Rated Frequency

 50Hz or 60Hz

Internal Components

  1. Core Tank Assembly
    • Core:Constructed from high-permeability, low-loss cold-rolled grain-oriented silicon steel laminations with a single-phase closed magnetic circuit structure, achieving extremely low no-load losses.
    • Windings:High-voltage copper wire/foil windings on the outer layer, low-voltage windings on the inner layer (with center tap), offering excellent insulation and heat dissipation performance.
    • Insulating Oil:Fully immersed design, serving as the dielectric medium for insulation, heat dissipation, and arc extinction.
  1. High-Voltage Side Components
  • Wiring & Operation:Equipped with HV bushing wells (2 for loop feed, 1 for radial feed) and a submersible load-break switch (operated via external handle).
  • Dual Protection:Adopts a "dual-fuse" protection scheme — externally replaceable Bay-O-Net fuses for overload/secondary short-circuit protection; internal ELSP current-limiting backup fuses to intercept severe short-circuit faults.
  • Voltage Regulation:Equipped with a no-load tap changer for manual adjustment of the turns ratio to adapt to grid voltage fluctuations.
  1. Low-Voltage Side Components
  • Output Terminals:Equipped with high-current bolt-type bushings (X1-X3 and neutral grounding terminal X0), with output voltage e.g. 120/240V.
  • Center Tap Grounding:The neutral wire is drawn out through the center tap of the low-voltage winding, simultaneously providing two voltage levels e.g. 120V (for household appliances) and 240V (for high-power equipment).
  1. Safety & Monitoring
  • Pressure Relief:Automatic PRV for pressure venting and explosion protection.
  • Status Monitoring:Integrated visual oil window + high-voltage dual-fuse oil temperature protection.

Structure and Design Features

Compact and Low-Profile: Small footprint, ideal for urban landscapes and confined commercial spaces.

Weather-Resistant Enclosure: Designed with durable materials and protective coatings to withstand rain, snow, high temperatures, and other environmental stresses, ensuring reliable operation under various climate conditions.

Safety: Lockable doors and concealed fasteners allow safe installation in residential areas and public spaces.

Easy Installation: The transformer is equipped with clearly marked high-voltage and low-voltage bushings that are easily accessible from the front, simplifying wiring and maintenance.

Primary Connection: High-voltage primary bushings are configured for seamless integration with overhead or underground utility feeders.

Secondary Connection: Low-voltage secondary terminals can be connected to commercial or residential distribution panels.

Manufactured to standard pad dimensions to ensure compatibility with existing infrastructure, facilitating easy replacement or new installation.

Dead Front Wiring: No exposed live parts on the high-voltage side. High-voltage leads are connected via fully insulated elbow connectors inserted into the front wall of the transformer. The surface of the connectors is absolutely safe to touch during operation (i.e., "dead front").

Highly Integrated Design:It is more than just a transformer body. The single-phase pad-mounted transformer integrates the HV load-break switch, dual-fuse protection, tap changer, and instrument transformers—all submersed in oil within the same sealed tank—in an extremely compact footprint, significantly reducing the required installation area.

ONAN Self-Cooling & Fully Sealed Design:Adopts the ONAN (Oil Natural Air Natural) cooling method, relying on natural oil circulation and air cooling. The enclosure is designed without an external oil conservator; instead, it accommodates oil expansion and contraction through a constant air cushion at the top of the tank or via mini-corrugated fins. This design completely isolates the insulating oil from the external atmosphere, achieving a "maintenance-free" or "low-maintenance" operation.

Insulating Oil

High-quality mineral insulating oil compliant with international standards.

Environmentally friendly insulating liquids such as natural ester (vegetable oil) or silicone oil are available as options.

Performance Advantages

Typical Applications

Residential Developments: Powering entire residential communities and townhouse complexes.

Commercial Centers: Supplying power to shopping malls, hospitals, and office buildings.

Renewable Energy: Used as step-up or step-down transformers in solar power plants and wind power installations.

Industrial Facilities: Providing stable power to manufacturing plants and large warehouses.

Frequently Asked Questions (FAQ)

Q: How do I choose the right capacity?

A: 10–100 kVA: Ideal for single-family homes, small commercial outlets, and lighting systems.

50–100 kVA: Suitable for multi-unit residential buildings, small shopping centers, and office parks.

100–167 kVA: Designed for large commercial projects, industrial sites, and utility service points.

Q: What maintenance is required for pad-mounted transformers?

A: These transformers require minimal maintenance, primarily involving periodic inspections for oil leaks, corrosion, and ensuring the enclosure remains secure and free of debris.

Q: What information is needed to obtain a quotation?

A: To receive a prompt and accurate quotation, please provide the following core parameters:

Rated Capacity (kVA)

Primary and Secondary Voltage Levels

Rated Frequency (50Hz or 60Hz)

Phase (Single-Phase or Three-Phase)

Winding Material: Both copper and aluminum windings are supported, each with distinct advantages in cost and performance.

Connection Group Label

Other Requirements: Such as applicable standards, special protection ratings, instrumentation accessories, etc.
Configuration Type: Radial Feed or Loop Feed.

Enclosure Material Selection:

  • Standard Steel: Standard option with anti-corrosion coating, typically available in landscape green or harbor grey.
  • 304/316 Stainless Steel: Recommended for coastal areas with high salt mist/humidity, or for indoor basement installations prone to moisture.

Installation Altitude & Temperature: If installed at altitudes exceeding 1,000 meters, or in environments where the temperature is consistently above 40°C or below -25°C, this must be declared in advance. The manufacturer will need to apply altitude corrections for external insulation or select special low-temperature sealing components.

 

Convenient Inquiry Process

You can contact us via our website, email, or other channels. You may also download and fill out the Inquiry Form from our official website, or provide your existing technical documents and drawings as the basis for requirements assessment. We will provide you with a quotation as soon as possible.

Production & Quality Control

Prior to formal production, we will provide detailed technical proposals including specifications, structural drawings, etc., for your review and confirmation.

We strictly implement the ISO quality management system, comprehensively monitoring raw materials, production processes, and finished product inspections to ensure every customized product delivers stable and reliable quality.

Delivery & After-Sales Service

Packaged in specialized wooden crates compliant with international standards, lined with high-performance moisture-proof materials to ensure absolute safety and dryness during long-distance transportation.

Detailed user manuals, maintenance manuals, and related documentation are provided with each shipment.

Remote or on-site installation guidance and commissioning services are available upon request.

Comprehensive after-sales support including technical consultation, fault diagnosis, and spare parts supply to ensure long-term stable operation of the product.

Product Certification

Who Are We

Kima Electric--Pioneers in intelligent power manufacturing.

Kima Electric is a global brand under Anhui Jinma Electric Technology Co., Ltd.. and is a professional manufacturer of transformers &power transmission and distribution equipment in China. Established in 2001 and located in Wuwei, Wuhu City, Anhui Province, China ,the company occupies a facility spanning 93 mu (approximately 62,000 square meters) with a building area of 51,000 square meters and a professional team of over 180 personnel. With over 20 years of industry expertise, we have developed a comprehensive production system, rigorous quality control, and a culture of continuous innovation. We are committed to providing global customers with exceptional quality assurance and professional services.

View Our Story
  • 0 +

    Factory Area (㎡)

  • 0 +

    Employees

  • 0 +

    Industry Experience

  • 0 +

    Countries Sale

Anhui Kima Electric Technology Co., Ltd.
Certificate Of Honour
  • Certification of Excellent Scenario Management System for Intelligent Manufacturing
  • Excellent Smart Factory Certification
  • Environmental Management System Certification Certificate
  • Occupational Health and Safety Management System Certification Certificate
  • Social Responsibility Management System Certification
  • Energy Management System Certification Certificate
  • Quality Management System Certification Certificate
  • Laboratory accreditation certificate
  • S11-M-1250-10  Certificate of Quality
  • S13-M-2500-10 Certificate of Quality
  • SCB13-2500-10 Certificate of Quality
  • SCB10-2000-10(Class H)Certificate of Quality
Latest News